Size Tolerances

(unit : mm)

  • Tolerances on Thickness

Thickness tolerances 

Thickness tolerances (symbol ET)

Up to
160

160 and over,
up to 250

Up to 80

80 and over,
up to 250

0.01 and over, up to and incl. 0.16

±0.015

±0.020

±0.010

±0.010

0.16 excess, up to and incl. 0.25

±0.020

±0.025

±0.010

±0.015

0.25 excess, up to and incl. 0.40

±0.025

±0.030

±0.015

±0.020

0.40 excess, up to and incl. 0.60

±0.030

±0.040

±0.020

±0.025

0.60 excess, up to and incl. 0.80

±0.040

±0.040

±0.025

±0.030

0.80 excess, up to and incl. 1.00

±0.040

±0.050

±0.030

±0.035

1.00 excess, up to and incl. 1.25

±0.050

±0.050

±0.035

±0.040

1.25 excess, up to and incl. 1.60

±0.050

±0.060

±0.040

±0.045

  • Tolerances on Width  

 

up to 80

80 and over, up to 160

160 and over, up to 250

0.60 up to and incl.

±0.10

±0.15

±0.20

0.60 up to and incl. 1.00

±0.15

±0.20

±0.25

1.00 up to and incl. 1.60

±0.20

±0.20

±0.30

 * For strips narrower than those specified above, please make a special order.
  
  
  • Permissible maximum value on Camber

- Soft (2D, BA finished)

Width

Maxmium value on camber

40 and over, up to 80

8 in any 2,000 length

80 and over

4 in any 2,000 length

- Hard temper (1/2H, 3/4H, H, EH)

Width

Maxmium value on camber

10 and over, up to 20

8 in any 1,000 length

 20 excess, up to 40

6 in any 1,000 length

 40 excess, up to 80

3 in any 1,000 length

80 and over

1 in any 1,000 length

 

  • Permissible maximum value on Coil Set (Curl)   
     
    - 100mm in any 1,000mm length

HOME